Nefit Boiler Error Code 4E 347
Code 4E 347 means that according to the measurement the return water is hotter than the flow water, which is not normally possible. Often the sensor connections have been swapped, for example after servicing, or a sensor is drifting. The boiler tries to restart itself after 10 minutes. If it happens more often, an installer must check the sensors.
Also shown as: 4E
Applies to: Nefit ProLine and TrendLine condensing boilers
Common causes
- The plugs of the flow and return sensors have been swapped
- One of the two sensors is reading incorrectly
- Air in the boiler around the sensors
What to check, in order
- Wait for the automatic restart after about 10 minutes and see whether the code stays away.
- Check the water pressure and bleed the radiators; top up if needed.
- If the code returns regularly, call a CO-certified installer; the sensors and their connections need to be checked.
Clear the code and test
- Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back.
- Make sure the boiler has power and the gas tap at the boiler is open.
- If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
- Press the reset button once and watch a full cycle: the boiler should start, heat the radiators or the tap water, and keep running without the code coming back.
When to call a professional
Most cases are solved by the checks above. Book a technician if any of these apply:
- The code comes back after you have run the checks and a test cycle.
- You smell burning, see sparks or scorch marks, or the breaker trips.
- Water is leaking and you cannot stop it.
- The fix needs panels opened beyond what your manual describes, or a part tested with a meter, and you are not set up for that.
When you call, give the brand, the code 4E 347, your model number (on a label on the type plate, usually at the bottom or on the side of the boiler) and the checks you already ran. It shortens the visit.
Parts that may be involved
Return temperature sensorFlow temperature sensor
Parts are model-specific. Find your model number first — usually on a label on the type plate, usually at the bottom or on the side of the boiler — and match the part to that number before ordering.
Questions people ask about 4E 347
What does 4E 347 mean on a Nefit boiler?
4E 347 means: The return temperature sensor has measured a higher heating water temperature than the flow temperature sensor; a restart follows after 10 minutes. Code 4E 347 means that according to the measurement the return water is hotter than the flow water, which is not normally possible. Often the sensor connections have been swapped, for example after servicing, or a sensor is drifting. The boiler tries to restart itself after 10 minutes. If it happens more often, an installer must check the sensors.
Can I fix Nefit 4E 347 myself?
Start yourself: the checks on this page cover the causes you can reach without opening the machine up. If they point to a faulty part, testing or replacing it is usually a technician job.
How do I clear Nefit 4E 347?
Fix what the checks above found first — pressure topped up, a radiator bled, the thermostat set right. Resetting without fixing the cause only brings the code back. Make sure the boiler has power and the gas tap at the boiler is open. If the water pressure is below 1.5 bar, top it up to between 1.5 and 2 bar with the filling loop, as your manual shows.
Sources checked
The meaning and checks for this code were checked against the sources above in November 2026. Codes vary by model and region; if your manual lists a different meaning for your exact model, follow the manual.